Difference between revisions of "Controller v2"
(→UART-based Controller) |
(→UART-based Controller) |
||
Line 24: | Line 24: | ||
== Control Commands == | == Control Commands == | ||
+ | |||
+ | <vardata> is an 8-120 bit unsigned integer. If less than 120 bit are sent, the date is 0-extended to 120 bit. | ||
+ | |||
+ | === SPI === | ||
+ | |||
+ | Format: 0x8X <vardata> | ||
+ | |||
+ | Sends <vardata> to SPI, asserting CS X. The read data are sent in a response packet of full length. | ||
+ | |||
+ | === GPOUT_HI === | ||
+ | |||
+ | Format: 0x70 <X> | ||
+ | |||
+ | Sets GPIO X to HI. | ||
+ | |||
+ | === GPOUT_LO === | ||
+ | |||
+ | Format: 0x71 <X> | ||
+ | |||
+ | sets GPIO X to LO. | ||
+ | |||
+ | === GPIN === | ||
+ | |||
+ | Format: 0x78 | ||
+ | |||
+ | Sends the value of all GPIN-pins as a bitmask in a response packet. | ||
== Motion Commands == | == Motion Commands == | ||
Line 35: | Line 61: | ||
=== NOTIFY === | === NOTIFY === | ||
− | Format: 0x61 | + | Format: 0x61 <vardata> |
+ | |||
+ | Echoes <vardata> to host as full 64 bit value. | ||
=== LOADALLREGS === | === LOADALLREGS === |
Revision as of 15:26, 29 July 2018
Contents
UART-based Controller
The controller has two UARTs, one for control and one for motion data. The motion-UART can use hardware flow control.
Framing
The framing is self synchronizing. Each frame ends with an EOF marker. Everywhere else the EOF marker is escaped.
Frame Format
- 1 byte sequence number
- n byte frame data
- 2 byte crc16 (CCITT) of frame data
- 0x7e as EOF marker
Escaping
Escaping is done by byte stuffing. Escape character is 0x7d. Bytes to be escaped are 0x7d and 0x7e. The escape character is following by the byte to by escaped XOR 0x20.
Sequence Number
The sequence number is echoed by the controller. The controller expects sequence numbers in ascending order. The sequence number has 7 bits. The special sequence nuber 0x80 resets the expected number in the controller to 0, so that the next frame has to be sent with the number 0x01. This is needed to achieve a resynchronization. The controller signals a receive error by setting the MSB in the response sequence number, echoing the received number.
Control Commands
<vardata> is an 8-120 bit unsigned integer. If less than 120 bit are sent, the date is 0-extended to 120 bit.
SPI
Format: 0x8X <vardata>
Sends <vardata> to SPI, asserting CS X. The read data are sent in a response packet of full length.
GPOUT_HI
Format: 0x70 <X>
Sets GPIO X to HI.
GPOUT_LO
Format: 0x71 <X>
sets GPIO X to LO.
GPIN
Format: 0x78
Sends the value of all GPIN-pins as a bitmask in a response packet.
Motion Commands
<vardata> is an 8-64 bit signed integer. If less than 64 bit are sent, the date is sign extended to 64 bit.
SET_ROUTING
Format: 0x60 <output channel> <controller source>
NOTIFY
Format: 0x61 <vardata>
Echoes <vardata> to host as full 64 bit value.
LOADALLREGS
Format: 0x70 <vardata>
Load all preload registers to vardata.
LOADCNT
Format: 0x71 <vardata>
Load the count register to vardata and latch all registers with the preload registers.
LOADREG
Format: 0x8X <vardata>
Load the preload register belonging to controller X with vardata.